Fluke 117 Electricians Multimeter adalah pengukur True-rms CAT III 600 V ringkas yang dilengkapi antarmuka yang mudah digunakan dengan lampu latar terang untuk lokasi kerja yang lebih gelap. Ini menghemat waktu Anda dan memungkinkan Anda berpindah dari satu pekerjaan ke pekerjaan lain dengan lebih cepat. Dengan memutar tombol dengan cepat, Anda dapat memperoleh pengukuran untuk:
- Resistance
- Continuity
- Frequency
- Capacitance
- Min/Max/Averag
SPESIFIKASI Fluke 117
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V | |
| Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
| Display | Digital: 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating temperature | -10°C to +50°C | |
| Storage temperature | -40°C to +60°C | |
| Battery type | 9 volt Alkaline, IEC 6LR61 | |
| Battery life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| Auto volts | Range/resolution | 600.0 V / 0.1 V |
| Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) | |
| AC millivolts¹ True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
| AC volts¹ True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. | |
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% + 1 | |
| Range/resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% + 2 | |
| Diode test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
| Accuracy | 1.9% + 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% + 20% | |
| Lo-Z capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% + 2 typical | |
| AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.5% + 3 20 A continuous overload for 30 seconds max | |
| DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.0% + 3 20 A continuous overload for 30 seconds max | |
| Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
| Accuracy | 0.1% + 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||